Back to top
Chemical Fume Hood

Chemical Fume Hood

Product Details:

  • Temperature Resistance Up to 120C
  • Features Chemical resistant, internal lighting, exhaust duct connection, adjustable sash height
  • Shape Rectangular
  • Control Type Manual (Sash and Switches)
  • Glass Type Toughened Safety Glass (Sash Window)
  • Speed Range Variable (fan/ventilation)
  • Display Type Analog (Airflow Indicator Gauge)
  • Click to View more
X

Chemical Fume Hood Price And Quantity

  • 1 Piece
  • Fixed
  • Chemical and abrasion resistant phenolic resin
  • < 65 dB
  • Single
  • Integrated centrifugal blower with duct
  • Provision provided inside the hood
  • Vertical sliding sash window
  • Built-in fluorescent lamp for better visibility
  • Fitted with airflow alarm and optional gas/vacuum taps
  • Floor Mounted
  • Approx. 180 kg
  • Grey and Blue (Epoxy Powder Coated)
  • 0.4-0.6 m/s (at face)
  • Aerodynamically designed for optimal airflow

Chemical Fume Hood Product Specifications

  • Manual (Sash and Switches)
  • Mild Steel (MS) with epoxy coated finish
  • 220 V AC
  • Toughened Safety Glass (Sash Window)
  • 1200 x 800 x 2300 mm
  • Chemical resistant, internal lighting, exhaust duct connection, adjustable sash height
  • Up to 120C
  • Epoxy-coated mild steel and chemical resistant work surface
  • Rectangular
  • Laboratory Fume Hood
  • 2200 W
  • Chemical Fume Hood
  • Analog (Airflow Indicator Gauge)
  • Single Phase
  • Variable (fan/ventilation)
  • Used for ventilation and handling hazardous fumes in laboratory environments
  • Fixed
  • Chemical and abrasion resistant phenolic resin
  • < 65 dB
  • Single
  • Integrated centrifugal blower with duct
  • Provision provided inside the hood
  • Vertical sliding sash window
  • Built-in fluorescent lamp for better visibility
  • Fitted with airflow alarm and optional gas/vacuum taps
  • Floor Mounted
  • Approx. 180 kg
  • Grey and Blue (Epoxy Powder Coated)
  • 0.4-0.6 m/s (at face)
  • Aerodynamically designed for optimal airflow

Chemical Fume Hood Trade Information

  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • as per order Per Month
  • as per order Week
  • Contact us for information regarding our sample policy
  • AS PER REQUIREMENTS
  • All India
  • MSME

Product Description

Chemical Fume Hood is one of the reliable engineering controls, widely used to protect workers against the gases, vapors, dusts and fumes developed within the hood. It is also utilized to remove the unwanted materials out through the laboratory exhaust system. It is used in laboratory ventilation applications to protect the workers using a clear sliding window. With durable and sturdy designs, it ensures to provide high-end performance for a long period of time.


Optimal Safety and Efficiency

This fume hood features advanced safety elements, including an airflow alarm and aerodynamically designed baffle system, ensuring continual protection against hazardous fumes. The toughened safety glass and chemical-resistant work surface offer enhanced user safety and product longevity, meeting the rigorous needs of laboratory operations.


User-Friendly Functionality

Equipped with built-in fluorescent lighting and adjustable vertical sash, the hood allows for clear visibility and easy operation. Manual controls and analog airflow indicator gauges provide direct monitoring and adjustment, while internal electrical outlets and optional gas/vacuum taps offer essential workplace convenience.

FAQs of Chemical Fume Hood:


Q: How does the integrated centrifugal blower with duct improve fume extraction in this hood?

A: The integrated centrifugal blower creates strong airflow, efficiently capturing and venting hazardous fumes through the connected duct system. This maintains a safe work environment by continuously removing contaminants from the laboratory workspace.

Q: What kind of chemicals and tasks is the phenolic resin work surface suitable for?

A: The chemical and abrasion-resistant phenolic resin work surface is ideal for handling corrosive reagents, solvents, and experimental materials commonly used in laboratories, providing reliable protection against chemical spills and physical wear.

Q: When should the airflow alarm be checked and what is its purpose?

A: The airflow alarm should be monitored during hood operation. Its purpose is to alert users to unsafe airflow levels, indicating when exhaust or ventilation is insufficient and prompting immediate corrective action to maintain safety.

Q: Where are the electrical outlets and optional gas/vacuum taps located in the fume hood?

A: The electrical outlets and optional gas/vacuum taps are installed inside the hood workspace, allowing convenient access to power and laboratory utilities directly within the ventilated zone for enhanced workflow efficiency.

Q: What is the process for adjusting the ventilation speed in this fume hood?

A: The fume hood features a variable-speed fan controlled manually. Users can adjust the ventilation speed using the provided switches and monitor performance via the analog airflow gauge for precise airflow control during operations.

Q: How does using this chemical fume hood benefit laboratory safety and compliance?

A: Using this fume hood reduces exposure to hazardous substances, ensures proper containment of fumes, and meets laboratory safety standards. Features like airflow alarms, toughened glass sash, and robust filtration contribute to regulatory compliance and personnel protection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail